Cleveland-motion-controls Clutch EMAG 9 User Manual

Browse online or download User Manual for Hardware Cleveland-motion-controls Clutch EMAG 9. Cleveland Motion Controls Clutch EMAG 9 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Nominal torque 12 N.m ft.lbf 9
Minimal torque 0.14 N.m ft.lbf 0.1
Coil resistance - 20°C
W
23
Rated current DC A 0.55
Rotor inertia 0.25.10
-3
kg.m
2
lb.ft
2
5.8 10
-3
Weight 2.8 kg lb 6.17
Heat dissipation
W * 65 170 220
continuous sustained
depending on external
part rotation speed
(RPM) 0 1000 2000
0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8
0
2
4
6
8
10
12
14
48
55
3,5
5,411 Ø
8h
55
Ø
3
61
92
3
1J 2
,61
4 E9
Ø 15 H7
46
+ 0,3
-0
7
30
+0,1
0
Application Notes
• Mounting must be made without any stress.
Lubricated for life (other internal lubrication not allowed).
The shaft should be lubricated upon assembly, to prevent seizing.
• Low DC current power supply for coil.
• The standard device is designed for horizontal shaft orientation,
and a minimal speed of 60 RPM. Maximum speed is 3000 RPM
(without exceeding the max. heat dissipation capability).
• For Engineering application, please contact our technical support.
• In normal use, the outside temperature of the device can increase up to 100°C,
without damage.
Clutch
EMAG 9
Specifications
* Heat dissipation is the mechanical power (P = cw ) maximum allowable.
301 Ø no °0
6
t
a 5M seloh
6
Max. deepness 12
mN eu
qr
oT
Current A
2 holes
Ø 4,1
Page view 0
1 2

Summary of Contents

Page 1 - Specifications

Nominal torque 12 N.m ft.lbf 9Minimal torque 0.14 N.m ft.lbf 0.1Coil resistance - 20°CW23Rated current DC A 0.55Rotor inertia 0.25.10-3kg.m2lb.ft 25.8

Page 2

Safety• If the device is to be used in dusty, humid or corrosive environment, special protection needs to be considered.Recommended mounting principle